[Header]	
Customer Name	ILLUMINA, INC.
Product Type	15033972
Date Manufactured	04/06/2013
Lot	WO0000109371679
DesignStudio ID	28826
Target Plexity	77
	
[Probes]
Gene Name	Transcript ID	Assay ID	Left Exon	Right Exon	Species	Build ID	Chromosome	Start Position	End Position	ULSO Sequence	ULSO Genomic Hits	DLSO Sequence	DLSO Genomic Hits	Probe Strand	Designer	Design Score	SNP Masking	Labels
CASP4	NM_033306	6612269	6	5	Homo sapiens	hg19	chr11	104819290	104817876	GACTTCATTGCTTTCTGCTCTTCAACG	3	GCACAATGGGCTCTATCTTCATC	3	MINUS	ILLUMINA	1.623	false	
PSEN1	NM_007318	6696264	4	5	Homo sapiens	hg19	chr14	73640381	73653599	TCCTGGTGGTTCTGTATAAATACAGGTG	1	GCCTGGCTTATTATATCATCTCTATTGTTG	1	PLUS	ILLUMINA	1.736	false	
EP300	NM_001429	6730292	0	1	Homo sapiens	hg19	chr22	41489064	41513219	CATCTCCGGCCCTCTCGGCGTC	2	TTTTGGCTCTCTATTTGACTTGGAGCAC	1	PLUS	ILLUMINA	1.338	false	
NCSTN	NM_015331	6801812	4	5	Homo sapiens	hg19	chr1	160320006	160321050	TTGAAGATGAAAATGAAACCAAAGTCATC	1	AACCTGAGTCAGAATGGCTCAGCA	2	PLUS	ILLUMINA	1.607	false	
PSEN2	NM_012486	6836335	11	12	Homo sapiens	hg19	chr1	227081792	227083159	ATACCACGCTGGCCTGCTTCGT	5	CTGACCCTCCTGCTGCTTGCTGTGTT	4	PLUS	ILLUMINA	1.317	false	
CASP7	NM_033340	6688018	1	2	Homo sapiens	hg19	chr10	115457330	115480828	AGACCGGTCCTCGTTTGTACCGT	1	TGTCACCATGCGATCCATCAAGA	2	PLUS	ILLUMINA	1.232	false	
FASLG	NM_000639	6690598	2	3	Homo sapiens	hg19	chr1	172633502	172634789	GGAGCTGAGGAAAGTGGCCCATTTAA	2	CAAGTCCAACTCAAGGTCCATGCCTCT	1	PLUS	ILLUMINA	1.903	false	
TP53	NM_001126114	6709182	7	6	Homo sapiens	hg19	chr17	7577524	7577127	ACCATCATCACACTGGAAGACTCCA	2	AATCTACTGGGACGGAACAGCTTTG	1	MINUS	ILLUMINA	1.771	false	
LRP1	NM_002332	6740035	19	20	Homo sapiens	hg19	chr12	57563058	57566987	GTGATGAGACACACGCCAACTGCA	1	GTGGCTGCCACACTGATGAGTT	16	PLUS	ILLUMINA	1.216	false	
A2M	NM_000014	6665747	1	0	Homo sapiens	hg19	chr12	9268387	9266117	CCACAGACGCCTCAGTCTCTGGAAAA	1	GCAGTATATGGTTCTGGTCCCCT	3	MINUS	ILLUMINA	1.538	false	
ABCA1	NM_005502	6847746	49	48	Homo sapiens	hg19	chr9	107547709	107546708	GACTACTCTGTTTCTCAGACAACACTTG	1	TATTTGTGAACTTTGCCAAGGACCAAAG	1	MINUS	ILLUMINA	1.94	false	
ACHE	NM_015831	6620921	3	2	Homo sapiens	hg19	chr7	100489983	100488922	CGATACTGGGCCAACTTTGCCC	4	CCCCGAGACCCCAAGGCCCCACAAT	1	MINUS	ILLUMINA	1.115	false	
ADAM10	NM_001110	6851734	2	1	Homo sapiens	hg19	chr15	59009808	58974471	ATTTTTACGTCTAGATTTCCATGCCCA	1	TGAAGAGGGACACTTCCCTTTTCAGT	1	MINUS	ILLUMINA	1.955	false	
ADAM9	NM_003816	6817426	12	13	Homo sapiens	hg19	chr8	38912058	38913122	AGTGTGCATATGGTGACTGTTGTAAAG	1	TCCTTCCAGGAGGTACTTTATGCCGA	1	PLUS	ILLUMINA	1.949	false	
APBA1	NM_001163	6629704	1	0	Homo sapiens	hg19	chr9	72287091	72132169	CGCGGACCCAGCTGTCAGGCAA	2	CCAGTGGAGCAAAATGAGAGCGCAGT	1	MINUS	ILLUMINA	1.301	false	
APBA3	NM_004886	6746653	10	9	Homo sapiens	hg19	chr19	3751219	3751063	ATCATCGAGCTGCTCACCGAGGCCTAT	1	GACGATGCCAGCTGCCACATAT	5	MINUS	ILLUMINA	1.376	false	
APBB1	NM_145689	6750827	10	9	Homo sapiens	hg19	chr11	6422609	6422275	GGACCACTCTAAACTTGTGGATGTCC	1	GGAATTCCCAGCGCCTAAGAATGAGTT	1	MINUS	ILLUMINA	1.936	false	
APBB2	NM_004307	6598209	17	16	Homo sapiens	hg19	chr4	40823922	40818249	GTAACGTGTCTGAGGCGGTGCA	5	CGATATCAGAAGTGCTTGGTAGCCA	1	MINUS	ILLUMINA	1.343	false	
APH1A	NM_001077628	6757227	4	3	Homo sapiens	hg19	chr1	150239790	150239577	CCATGGAGACTCACCCTATTACTTCCT	1	CTTTCTGACAGCAGCCATTATCCTG	2	MINUS	ILLUMINA	1.875	false	
APLP1	NM_005166	6848927	2	3	Homo sapiens	hg19	chr19	36361902	36362176	CCACCAGGTTGTGCCCTTCCGCT	3	GAGTGAGGCCCTGCTGGTGCCTGAA	3	PLUS	ILLUMINA	1.243	false	
APLP2	NM_001642	6657680	11	12	Homo sapiens	hg19	chr11	130003591	130005497	CTTATGTAGCCCAAGAAATTCAAGAGG	1	GGAGCAGCGTGCAGATATGGACCAGTT	1	PLUS	ILLUMINA	1.898	false	
APOA1	NM_000039	6825681	2	1	Homo sapiens	hg19	chr11	116708088	116707845	CTGACCTTGGCCGTGCTCTTCCTGA	2	AGGCTCGGCATTTCTGGCAGCAA	2	MINUS	ILLUMINA	1.37	false	
APOE	NM_000041	6666762	2	3	Homo sapiens	hg19	chr19	45411177	45411828	GCTGCTCAGCTCCCAGGTCACCCAGGAA	1	GAGACCATGAAGGAGTTGAAGGCCTA	1	PLUS	ILLUMINA	1.684	false	
APP	NM_000484	6696134	10	9	Homo sapiens	hg19	chr21	27348301	27347502	ACTTGCCTAAAGCTGATAAGAAGGCAG	2	GTGGAATCTTTGGAACAGGAAGCAG	2	MINUS	ILLUMINA	1.884	false	
BACE1	NM_138973	6722098	7	6	Homo sapiens	hg19	chr11	117161644	117161352	AGTCCTTCCGCATCACCATCCTT	6	AATACCTGCGGCCAGTGGAAGAT	2	MINUS	ILLUMINA	1.243	false	
BACE2	NM_012105	6765192	1	2	Homo sapiens	hg19	chr21	42598247	42609481	CACTCCTACATAGACACGTACTTTGAC	1	CTCCAAGGGCTTTGACGTCACAGTGAA	1	PLUS	ILLUMINA	1.946	false	
BCHE	NM_000055	6665857	2	1	Homo sapiens	hg19	chr3	165547345	165504064	AGATCCATAGTGAAACGGTGGGCAAA	1	TGAGACTCAGAACAATAGCACAAGCTG	2	MINUS	ILLUMINA	1.963	false	
CAMK2A	NM_015981	6691588	17	16	Homo sapiens	hg19	chr5	149607791	149602751	GAGGGCCTGGACTTCCATCGATTCTATTT	1	CCGGAACAGCAAGCCCGTGCACA	1	MINUS	ILLUMINA	1.386	false	
CAPN1	NM_005186	6731351	20	21	Homo sapiens	hg19	chr11	64978309	64978755	ATCTGGATGGAGTTGTGACCTTTGAC	1	GGTTGCAGCTGACCATGTTTGCAT	2	PLUS	ILLUMINA	1.731	false	
CDK5	NM_004935	6726489	1	0	Homo sapiens	hg19	chr7	150754933	150754218	GCAGAAATACGAGAAACTGGAAAAGATTGG	2	CCTACGGAACTGTGTTCAAGGCCAAAA	2	MINUS	ILLUMINA	1.752	false	
CHAT	NM_020985	6783366	8	9	Homo sapiens	hg19	chr10	50854690	50856584	GGCCAATCGCTGGTACGACAAGT	2	TGGGCCGAGACGGCACCTGCGGTGT	1	PLUS	ILLUMINA	1.154	false	
CLU	NR_045494	6691091	8	7	Homo sapiens	hg19	chr8	27456011	27455730	GAGAAAGCGCTGCAGGAATACCGCAAAAA	1	GGATGTTGCTTTTGCACCTACGG	4	MINUS	ILLUMINA	1.468	false	
CTSB	NM_147780	6634132	8	7	Homo sapiens	hg19	chr8	11705608	11705289	TGGTTTCTGGTGGCCTCTATGAATC	2	ATCCCTCCCTGTGAGCACCACGTCAA	1	MINUS	ILLUMINA	1.746	false	
CTSD	NM_001909	6784540	8	7	Homo sapiens	hg19	chr11	1775061	1774860	AGCTGTCCCCAGAGGACTACAC	9	GGAAGACCCTCTGCCTGAGCGGCTTCAT	1	MINUS	ILLUMINA	1.251	false	
DRD2	NM_000795	6850603	2	1	Homo sapiens	hg19	chr11	113295121	113288820	ACACTGGTCATGCCCTGGGTTGTCTA	1	GGAAATTCAGCAGGATTCACTGTGAC	1	MINUS	ILLUMINA	1.88	false	
ERN1	NM_001433	6628764	2	1	Homo sapiens	hg19	chr17	62175517	62158148	AAGAGGACAGGCTCAATCAAATGGAC	1	AGAAGATCCAGTCCTGCAGGTCCCAA	1	MINUS	ILLUMINA	1.883	false	
GAL	NM_015973	6604113	3	4	Homo sapiens	hg19	chr11	68455539	68456345	AGCTGCGGCCCGAAGATGACATGAAA	1	CTTTGACAGGTCCATACCTGAAAAC	1	PLUS	ILLUMINA	1.782	false	
GAP43	NM_001130064	6770582	2	3	Homo sapiens	hg19	chr3	115395425	115439676	CTGGGGAGAGCAGCCAAGCTGAAGAGAA	1	ATGAAACCAAACCTAAGGAAAGTGCCC	1	PLUS	ILLUMINA	1.851	false	
GNB1	NM_002074	6810470	11	10	Homo sapiens	hg19	chr1	1718793	1718454	AGCTTCCTCAAGATCTGGAACTAACG	3	TGGAGACTGGAAGACCATTCCAACTT	1	MINUS	ILLUMINA	1.936	false	
GRIN1	NM_001185090	6790222	0	1	Homo sapiens	hg19	chr9	140034162	140036491	CTCTGTCGGTGTGCGAGGACCTCATCT	1	TCTACGCCATCCTAGTTAGCCATCCA	1	PLUS	ILLUMINA	1.814	false	
GSK3B	NM_002093	6801978	1	0	Homo sapiens	hg19	chr3	119812228	119721043	GCAGCCTTCAGCTTTTGGCAGCATGAAA	1	TGACAACAGTGGTGGCAACTCCT	5	MINUS	ILLUMINA	1.534	false	
HSD17B10	NM_004493	6764599	3	2	Homo sapiens	hg19	chrX	53459224	53459037	ACCTTGGAAGACTTCCAGCGAGTTCTT	1	GAATCTCATGGGCACCTTCAATGTGA	1	MINUS	ILLUMINA	1.944	false	
HSP90AA1	NM_001017963	6785690	7	6	Homo sapiens	hg19	chr14	102550768	102550278	ATAACTGTGAGGAGCTAATCCCTGA	6	GGTGGTAGACTCGGAGGATCTCCCTCTAAA	6	MINUS	ILLUMINA	1.616	false	
HSPA5	NM_005347	6856141	7	6	Homo sapiens	hg19	chr9	128000456	127999401	GATAATCAACCAACTGTTACAATCAAGGTC	2	AGACCCCTGACAAAAGACAATCATCTTC	3	MINUS	ILLUMINA	1.737	false	
HTR1A	NM_000524	6737885	0	0	Homo sapiens	hg19	chr5	63256943	63256887	GGAGCTTTCTACATCCCGCTGCT	5	GGTTCTCTATGGGCGCATATTCCGA	1	MINUS	ILLUMINA	1.466	false	
HTR3A	NM_001161772	6732125	3	4	Homo sapiens	hg19	chr11	113852000	113853869	AGCATCTGGGTCCCGGACATTCTCAT	2	GTGGATGTGGGGAAGTCTCCAAATATC	1	PLUS	ILLUMINA	1.901	false	
IDE	NM_004969	6712253	18	17	Homo sapiens	hg19	chr10	94230047	94228709	CATTGAAGCCCTTCTCCATGGAAACA	1	AATTATGCAGATGGTTGAAGACACCCTC	1	MINUS	ILLUMINA	1.939	false	
INSR	NM_000208	6823428	1	0	Homo sapiens	hg19	chr19	7293841	7267870	TGCTACTGGGCGCCGCGGGCCACCTGTA	1	ATGGATATCCGGAACAACCTCACTAGG	1	MINUS	ILLUMINA	1.542	false	
LPL	NM_000237	6743625	1	2	Homo sapiens	hg19	chr8	19805821	19809322	CAAAACCTTCATGGTGATCCATGGCT	1	TGGGTGCCAAAACTTGTGGCCG	5	PLUS	ILLUMINA	1.422	false	
LRP6	NM_002336	6654786	6	5	Homo sapiens	hg19	chr12	12334004	12332887	GGGCTATTGTGTTAGATCCCATGGTT	1	GTATTGGACTGACTGGGGAGAAA	8	MINUS	ILLUMINA	1.595	false	
LRP8	NM_004631	6739915	7	6	Homo sapiens	hg19	chr1	53736933	53736800	AGGCTTCCAGCTCCTGGACCAGAAGA	1	CATTGATGAGTGCAAGGACCCAGAT	2	MINUS	ILLUMINA	1.754	false	
MAPT	NM_001123066	6649017	0	1	Homo sapiens	hg19	chr17	43972024	44039726	CTCCCGTCCTCGCCTCTGTCGACTAT	1	CAGGATGGCTGAGCCCCGCCAGGAGTT	1	PLUS	ILLUMINA	1.543	false	
MPO	NM_000250	6686102	9	8	Homo sapiens	hg19	chr17	56350802	56350252	TTTGCCTCCTGGAGGGTCGTGCTGGAA	1	CATTGACCCCATCCTCCGGGGCCT	4	MINUS	ILLUMINA	1.447	false	
NAE1	NM_001018159	6838618	20	19	Homo sapiens	hg19	chr16	66839710	66836983	GAGCCACATACCATTGCTGCATTCTT	1	CAAGAGGTCATCAAAATAATCACCAAAC	1	MINUS	ILLUMINA	1.913	false	
PKP4	NM_003628	6818731	0	1	Homo sapiens	hg19	chr2	159313688	159389722	CCCTGATCCCTGGAGCGACGAC	3	GAATGCCAGCTCCTGAGCAGGCCTCATT	1	PLUS	ILLUMINA	1.248	false	
PLAT	NM_000930	6772976	6	5	Homo sapiens	hg19	chr8	42044950	42042647	ATCAGGCTGGGCCTGGGGAACCACAACTA	1	GCCCTGGTGCTACGTCTTTAAGG	2	MINUS	ILLUMINA	1.331	false	
PLAU	NM_002658	6845100	6	7	Homo sapiens	hg19	chr10	75673482	75673777	CCTTGCTGGGTGATCAGCGCCACACA	1	GGAGGACTACATCGTCTACCTGGGT	1	PLUS	ILLUMINA	1.638	false	
PLG	NM_000301	6608882	0	1	Homo sapiens	hg19	chr6	161123349	161127466	GAAGTGGTTCTTCTACTTCTTTTATTTCTG	7	TCAAGGAGAGCCTCTGGATGACTATGT	5	PLUS	ILLUMINA	1.728	false	
PRKCB	NM_212535	6796434	14	15	Homo sapiens	hg19	chr16	24196861	24202434	CAAGGAAGCTGTGGCCATCTGCAAA	4	CTGATGACCAAACACCCAGGCAAA	3	PLUS	ILLUMINA	1.621	false	
PRKCD	NM_006254	6683140	2	3	Homo sapiens	hg19	chr3	53212521	53213633	GTGCCGTGAAGATGAAGGAGGC	10	TGGTGCAGAAGAAGCCGACCATGTAT	1	PLUS	ILLUMINA	1.401	false	
PRKCE	NM_005400	6622557	1	2	Homo sapiens	hg19	chr2	46070178	46203607	GATCTCTCAGGGTCGTCGGGTGAA	1	AAGAGCGTGTGTTCAGGGAACGCAT	1	PLUS	ILLUMINA	1.564	false	
PRKCG	NM_002739	6795615	0	1	Homo sapiens	hg19	chr19	54385882	54386444	AGCCCACCTTCTGCAGCCACTG	93	GGTATCGGAAAGCAGGGCCTGCAATGT	1	PLUS	ILLUMINA	1.327	false	
PRKCI	NM_002740	6682717	2	3	Homo sapiens	hg19	chr3	169977812	169981204	TGAGCTAAACAAGGATTCTGAACTCTTG	2	CAGAACGTCCTGGGATGCCTTGT	5	PLUS	ILLUMINA	1.567	false	
PRKCQ	NM_006257	6776116	11	10	Homo sapiens	hg19	chr10	6525434	6521087	CACAAAATGTTGGGGAAAGGAAGTTTTG	1	AGAATTCAAGAAAACCAATCAATTTTTCGC	1	MINUS	ILLUMINA	1.695	false	
PRKCZ	NM_002744	6706722	16	17	Homo sapiens	hg19	chr1	2116099	2116404	GTTCACCAGCGAGCCCGTGCAGCTGA	1	CCAGTCAGAGTTCGAAGGCTTTG	2	PLUS	ILLUMINA	1.35	false	
SERPINA3	NM_001085	6611283	3	4	Homo sapiens	hg19	chr14	95088803	95089974	GGGCCAGGAACCTAGCAGTCTC	8	GTGGTCCATAAGGCTGTGCTTGATGTA	1	PLUS	ILLUMINA	1.418	false	
SNCA	NM_001146055	6604299	2	1	Homo sapiens	hg19	chr4	90756727	90749311	GAAAGACAAAAGAGGGTGTTCTCTATG	1	TCCAAAACCAAGGAGGGAGTGGT	9	MINUS	ILLUMINA	1.615	false	
SNCB	NM_001001502	6828282	6	5	Homo sapiens	hg19	chr5	176048243	176047817	AAGGGGAGAGTTATGAGGACCCA	5	AGGAATATCAGGAGTATGAGCCAGAGG	1	MINUS	ILLUMINA	1.61	false	
SOD2	NM_001024465	6730823	4	3	Homo sapiens	hg19	chr6	160105918	160103645	GTCCAAATCAGGATCCACTGCAAGGAA	1	CCTTATTCCACTGCTGGGGATTGAT	1	MINUS	ILLUMINA	1.868	false	
TACR1	NM_001058	6666168	2	1	Homo sapiens	hg19	chr2	75347738	75280845	CGAATGGCCAGAGCATCCGAACAAGATTTA	1	GTGACTGTGCTGATCTACTTCCTCC	2	MINUS	ILLUMINA	1.622	false	
ABL1	NM_007313	6607158	3	4	Homo sapiens	hg19	chr9	133738398	133747556	GACGGTGGCCGTGAAGACCTTGAA	1	GTGGAAGAGTTCTTGAAAGAAGCTGC	2	PLUS	ILLUMINA	1.675	false	
CASP3	NM_004346	6622272	7	6	Homo sapiens	hg19	chr4	185552223	185550612	CCGACTTCTTGTATGCATACTCCACA	1	AATTCAAAGGATGGCTCCTGGTTCATC	1	MINUS	ILLUMINA	1.966	false	
FAS	NM_000043	6886514	8	NA	Homo sapiens	hg19	chr10	90774742	90774797	GCAGAATTTAAATAAGGCTCTACCTCA	1	CCTTTGCACAGTTTATTGGTGTCAT	2	PLUS	ILLUMINA	1.867	false	
IL1A	NM_000575	6634703	1	0	Homo sapiens	hg19	chr2	113542054	113541329	AGGGAGTCATTTCATTGGCGTTTGAG	1	AGTCAAGATGGCCAAAGTTCCAGACA	1	MINUS	ILLUMINA	1.933	false	
INS	NM_001185098	6869713	1	NA	Homo sapiens	hg19	chr11	2181179	2181123	CCTTGGCCCTGGAGGGGTCCCTGCAGAA	1	TGGCATTGTGGAACAATGCTGTACCA	1	MINUS	ILLUMINA	1.625	false	
PRKCA	NM_002737	6661457	1	2	Homo sapiens	hg19	chr17	64302221	64492356	GGGAAACAAGGCTTCCAGTGCCAAGTTT	1	GGTCCACAAGAGGTGCCATGAATTT	2	PLUS	ILLUMINA	1.809	false	
BDNF	NM_001143816	6925057	1	NA	Homo sapiens	hg19	chr11	27678231	27678174	AAGGTAGAGCCCTGTATCAACCCAGAA	1	ATCAGAACAGGAATCCACATTGC	8	MINUS	ILLUMINA	1.613	false	
[Targets]
Gene Name	Transcript ID	Assay ID	Assay Position	Validated	Left Exon	Right Exon	Probe Strand	Target Sequence
CASP4	NM_033306	6612269	NA	false	6	5	MINUS	GATGAAGATAGAGCCCATTGTGCTGTCTCTCCAGGACACGTTGTGTGGCGTTGAAGAGCAGAAAGCAATGAAGTC
PSEN1	NM_007318	6696264	CENTER	false	4	5	PLUS	CAACAATAGAGATGATATAATAAGCCAGGCATGGATGACCTTATAGCACCTGTATTTATACAGAACCACCAGGA
EP300	NM_001429	6730292	FIVE_PRIME	false	0	1	PLUS	GTGCTCCAAGTCAAATAGAGAGCCAAAATCTGTGCCATCGCTGGCGGACGCCGAGAGGGCCGGAGATG
NCSTN	NM_015331	6801812	CENTER	false	4	5	PLUS	TGCTGAGCCATTCTGACTCAGGTTGTGATCTTGATAGCACTGCTTGATGACTTTGGTTTCATTTTCATCTTCAA
PSEN2	NM_012486	6836335	THREE_PRIME	false	11	12	PLUS	AACACAGCAAGCAGCAGGAGGGTCAGACACAAGCCAATGAGGATGGCCACGAAGCAGGCCAGCGTGGTAT
CASP7	NM_033340	6688018	FIVE_PRIME	false	1	2	PLUS	TCTTGATGGATCGCATGGTGACATTTTTCTTCTTCTTACTGAAGAGGGACGGTACAAACGAGGACCGGTCT
FASLG	NM_000639	6690598	THREE_PRIME	false	2	3	PLUS	AGAGGCATGGACCTTGAGTTGGACTTGCCTGTTAAATGGGCCACTTTCCTCAGCTCC
TP53	NM_001126114	6709182	THREE_PRIME	false	7	6	MINUS	CAAAGCTGTTCCGTCCCAGTAGATTACCACTGGAGTCTTCCAGTGTGATGATGGT
LRP1	NM_002332	6740035	CENTER	false	19	20	PLUS	AACTCATCAGTGTGGCAGCCACCAGGGGGCCTCGTGGCCTGGTTGGTGCAGTTGGCGTGTGTCTCATCAC
A2M	NM_000014	6665747	FIVE_PRIME	false	1	0	MINUS	AGGGGACCAGAACCATATACTGCGGTTTTCCAGAGACTGAGGCGTCTGTGG
ABCA1	NM_005502	6847746	THREE_PRIME	false	49	48	MINUS	CTTTGGTCCTTGGCAAAGTTCACAAATACTTGGTCAAGTGTTGTCTGAGAAACAGAGTAGTC
ACHE	NM_015831	6620921	FIVE_PRIME	false	3	2	MINUS	ATTGTGGGGCCTTGGGGTCTCGGGGCTCATTGGGATCCCCTGTGCGGGCAAAGTTGGCCCAGTATCG
ADAM10	NM_001110	6851734	FIVE_PRIME	false	2	1	MINUS	ACTGAAAAGGGAAGTGTCCCTCTTCATTCGTAGGTTGAAATGTCTTCCATGGGCATGGAAATCTAGACGTAAAAAT
ADAM9	NM_003816	6817426	CENTER	false	12	13	PLUS	TCGGCATAAAGTACCTCCTGGAAGGAACCGACAGTCTTTACAACAGTCACCATATGCACACT
APBA1	NM_001163	6629704	FIVE_PRIME	false	1	0	MINUS	ACTGCGCTCTCATTTTGCTCCACTGGGCTTGCCTGACAGCTGGGTCCGCG
APBA3	NM_004886	6746653	THREE_PRIME	false	10	9	MINUS	ATATGTGGCAGCTGGCATCGTCTTGATATGCACCTCGCCATAGGCCTCGGTGAGCAGCTCGATGAT
APBB1	NM_145689	6750827	NA	false	10	9	MINUS	AACTCATTCTTAGGCGCTGGGAATTCCACTTGGAAAGGGACATCCACAAGTTTAGAGTGGTCC
APBB2	NM_004307	6598209	THREE_PRIME	false	17	16	MINUS	TGGCTACCAAGCACTTCTGATATCGTAACATGCAGGCGGCCTGCACCGCCTCAGACACGTTAC
APH1A	NM_001077628	6757227	FIVE_PRIME	false	4	3	MINUS	CAGGATAATGGCTGCTGTCAGAAAGGCTGAAGTCAGGAAGTAATAGGGTGAGTCTCCATGG
APLP1	NM_005166	6848927	FIVE_PRIME	false	2	3	PLUS	TTCAGGCACCAGCAGGGCCTCACTCACAAATTCACCAGGCAGGCAGCGGAAGGGCACAACCTGGTGG
APLP2	NM_001642	6657680	CENTER	false	11	12	PLUS	AACTGGTCCATATCTGCACGCTGCTCCTGAAGGAGCTCATCAATTTCCTCTTGAATTTCTTGGGCTACATAAG
APOA1	NM_000039	6825681	FIVE_PRIME	false	2	1	MINUS	TTGCTGCCAGAAATGCCGAGCCTGGCTCCCCGTCAGGAAGAGCACGGCCAAGGTCAG
APOE	NM_000041	6666762	THREE_PRIME	false	2	3	PLUS	TAGGCCTTCAACTCCTTCATGGTCTCGTCCATCAGCGCCCTCAGTTCCTGGGTGACCTGGGAGCTGAGCAGC
APP	NM_000484	6696134	NA	false	10	9	MINUS	CTGCTTCCTGTTCCAAAGATTCCACTTTCTCCTGGAAATGCTGGATAACTGCCTTCTTATCAGCTTTAGGCAAGT
BACE1	NM_138973	6722098	NA	false	7	6	MINUS	ATCTTCCACTGGCCGCAGGTATTGCTGCGGAAGGATGGTGATGCGGAAGGACT
BACE2	NM_012105	6765192	CENTER	false	1	2	PLUS	TTCACTGTGACGTCAAAGCCCTTGGAGCGGTATGTGCTAGACCTCTCTGTGTCAAAGTACGTGTCTATGTAGGAGTG
BCHE	NM_000055	6665857	FIVE_PRIME	false	2	1	MINUS	CAGCTTGTGCTATTGTTCTGAGTCTCATTTGGATTCCCATATTTTGCAAAATTTGCCCACCGTTTCACTATGGATCT
CAMK2A	NM_015981	6691588	THREE_PRIME	false	17	16	MINUS	TGTGCACGGGCTTGCTGTTCCGGGACCACAGGTTTTCAAAATAGAATCGATGGAAGTCCAGGCCCTC
CAPN1	NM_005186	6731351	THREE_PRIME	false	20	21	PLUS	ATGCAAACATGGTCAGCTGCAACCACTTAAACAAGTCAAAGGTCACAACTCCATCCAGAT
CDK5	NM_004935	6726489	FIVE_PRIME	false	1	0	MINUS	TTTTGGCCTTGAACACAGTTCCGTAGGTGCCTTCCCCAATCTTTTCCAGTTTCTCGTATTTCTGC
CHAT	NM_020985	6783366	CENTER	false	8	9	PLUS	ACACCGCAGGTGCCGTCTCGGCCCACCACAAACTGCAGGGACTTGTCGTACCAGCGATTGGCC
CLU	NR_045494	6691091	THREE_PRIME	false	8	7	MINUS	CCGTAGGTGCAAAAGCAACATCCACATCTCACTCCTCCCGGTGCTTTTTGCGGTATTCCTGCAGCGCTTTCTC
CTSB	NM_147780	6634132	NA	false	8	7	MINUS	TTGACGTGGTGCTCACAGGGAGGGATGGAGTACGGTCTGCACCCTACATGGGATTCATAGAGGCCACCAGAAACCA
CTSD	NM_001909	6784540	THREE_PRIME	false	8	7	MINUS	ATGAAGCCGCTCAGGCAGAGGGTCTTCCCGGCCTGCGACACCTTGAGCGTGTAGTCCTCTGGGGACAGCT
DRD2	NM_000795	6850603	FIVE_PRIME	false	2	1	MINUS	GTCACAGTGAATCCTGCTGAATTTCCACTCACCTACCACCTCCAGGTAGACAACCCAGGGCATGACCAGTGT
ERN1	NM_001433	6628764	FIVE_PRIME	false	2	1	MINUS	TTGGGACCTGCAGGACTGGATCTTCTTTTAAAGTCCATTTGATTGAGCCTGTCCTCTT
GAL	NM_015973	6604113	CENTER	false	3	4	PLUS	GTTTTCAGGTATGGACCTGTCAAAGCTTCCTGGTTTCATGTCATCTTCGGGCCGCAGCT
GAP43	NM_001130064	6770582	FIVE_PRIME	false	2	3	PLUS	GGGCACTTTCCTTAGGTTTGGTTTCATCTACAGCTTCTATGTTCTCTTCAGCTTGGCTGCTCTCCCCAG
GNB1	NM_002074	6810470	THREE_PRIME	false	11	10	MINUS	AAGTTGGAATGGTCTTCCAGTCTCCATGGCATCCACATGCTACTGGCGTTAGTTCCAGATCTTGAGGAAGCT
GRIN1	NM_001185090	6790222	FIVE_PRIME	false	0	1	PLUS	TGGATGGCTAACTAGGATGGCGTAGACCTGGCTGGAGATGAGGTCCTCGCACACCGACAGAG
GSK3B	NM_002093	6801978	FIVE_PRIME	false	1	0	MINUS	AGGAGTTGCCACCACTGTTGTCACCTTGCTGCCGTCCTTGTCTCTGCTAACTTTCATGCTGCCAAAAGCTGAAGGCTGC
HSD17B10	NM_004493	6764599	CENTER	false	3	2	MINUS	TCACATTGAAGGTGCCCATGAGATTCACATCAAGAACTCGCTGGAAGTCTTCCAAGGT
HSP90AA1	NM_001017963	6785690	NA	false	7	6	MINUS	TTTAGAGGGAGATCCTCCGAGTCTACCACCCCTCTAATGAAGTTCAGATATTCAGGGATTAGCTCCTCACAGTTAT
HSPA5	NM_005347	6856141	THREE_PRIME	false	7	6	MINUS	GAAGATGATTGTCTTTTGTCAGGGGTCTTTCACCTTCATAGACCTTGATTGTAACAGTTGGTTGATTATC
HTR1A	NM_000524	6737885	FIVE_PRIME	false	0	0	MINUS	TCGGAATATGCGCCCATAGAGAACCAGCATGAGCAGCAGCGGGATGTAGAAAGCTCC
HTR3A	NM_001161772	6732125	CENTER	false	3	4	PLUS	GATATTTGGAGACTTCCCCACATCCACGAACTCATTGATGAGAATGTCCGGGACCCAGATGCT
IDE	NM_004969	6712253	NA	false	18	17	MINUS	GAGGGTGTCTTCAACCATCTGCATAATTCCTAATGCAGCCTGCTTTGTTATGTTTCCATGGAGAAGGGCTTCAATG
INSR	NM_000208	6823428	FIVE_PRIME	false	1	0	MINUS	CCTAGTGAGGTTGTTCCGGATATCCATGCCGGGACACACCTCTCCGGGGTACAGGTGGCCCGCGGCGCCCAGTAGCA
LPL	NM_000237	6743625	FIVE_PRIME	false	1	2	PLUS	CGGCCACAAGTTTTGGCACCCAACTCTCATACATTCCTGTTACCGTCCAGCCATGGATCACCATGAAGGTTTTG
LRP6	NM_002336	6654786	NA	false	6	5	MINUS	TTTCTCCCCAGTCAGTCCAATACATGTACCCAACCATGGGATCTAACACAATAGCCC
LRP8	NM_004631	6739915	NA	false	7	6	MINUS	ATCTGGGTCCTTGCACTCATCAATGTCGCCACAGGTCTTCTGGTCCAGGAGCTGGAAGCCT
MAPT	NM_001123066	6649017	FIVE_PRIME	false	0	1	PLUS	AACTCCTGGCGGGGCTCAGCCATCCTGGTTCAAAGTTCACCTGATAGTCGACAGAGGCGAGGACGGGAG
MPO	NM_000250	6686102	THREE_PRIME	false	9	8	MINUS	AGGCCCCGGAGGATGGGGTCAATGCCACCTTCCAGCACGACCCTCCAGGAGGCAAA
NAE1	NM_001018159	6838618	THREE_PRIME	false	20	19	MINUS	GTTTGGTGATTATTTTGATGACCTCTTGAGCAGCAGCTCCCCCCAAGAATGCAGCAATGGTATGTGGCTC
PKP4	NM_003628	6818731	FIVE_PRIME	false	0	1	PLUS	AATGAGGCCTGCTCAGGAGCTGGCATTCCTCTTTCCAGCTTAGGCAGCGGCCGTCGTCGCTCCAGGGATCAGGG
PLAT	NM_000930	6772976	NA	false	6	5	MINUS	CCTTAAAGACGTAGCACCAGGGCTTTGAGTCTCGATCTGGGTTTCTGCAGTAGTTGTGGTTCCCCAGGCCCAGCCTGAT
PLAU	NM_002658	6845100	CENTER	false	6	7	PLUS	ACCCAGGTAGACGATGTAGTCCTCCTTCTTTGGGTAATCAATGAAGCAGTGTGTGGCGCTGATCACCCAGCAAGG
PLG	NM_000301	6608882	FIVE_PRIME	false	0	1	PLUS	ACATAGTCATCCAGAGGCTCTCCTTGACCTGATTTCAGAAATAAAAGAAGTAGAAGAACCACTTC
PRKCB	NM_212535	6796434	THREE_PRIME	false	14	15	PLUS	TTTGCCTGGGTGTTTGGTCATCAGCCCTTTGCAGATGGCCACAGCTTCCTTG
PRKCD	NM_006254	6683140	FIVE_PRIME	false	2	3	PLUS	ATACATGGTCGGCTTCTTCTGCACCAGTGTTTTCCCACGCTCTGTGCTGAGCGCCTCCTTCATCTTCACGGCAC
PRKCE	NM_005400	6622557	FIVE_PRIME	false	1	2	PLUS	ATGCGTTCCCTGAACACACGCTCTTCATTGTCTTTAGGGGCTTCACCCGACGACCCTGAGAGATC
PRKCG	NM_002739	6795615	FIVE_PRIME	false	0	1	PLUS	ACATTGCAGGCCCTGCTTTCCGATACCCCAGATGAAGTCGGTGCAGTGGCTGCAGAAGGTGGGCT
PRKCI	NM_002740	6682717	CENTER	false	2	3	PLUS	ACAAGGCATCCCAGGACGTTCTGGTACACAAGGGAACACATGAATCAAGAGTTCAGAATCCTTGTTTAGCTCA
PRKCQ	NM_006257	6776116	NA	false	11	10	MINUS	GCGAAAAATTGATTGGTTTTCTTGAATTCTGCCAGGAAGACCTTGCCAAAACTTCCTTTCCCCAACATTTTGTG
PRKCZ	NM_002744	6706722	THREE_PRIME	false	16	17	PLUS	CAAAGCCTTCGAACTCTGACTGGTCGATCCTCTTTATGGCATCCTCATCGTCTGGGGTCAGCTGCACGGGCTCGCTGGTGAAC
SERPINA3	NM_001085	6611283	THREE_PRIME	false	3	4	PLUS	TACATCAAGCACAGCCTTATGGACCACCTGGGAGACTGCTAGGTTCCTGGCCC
SNCA	NM_001146055	6604299	FIVE_PRIME	false	2	1	MINUS	ACCACTCCCTCCTTGGTTTTGGAGCCTACATAGAGAACACCCTCTTTTGTCTTTC
SNCB	NM_001001502	6828282	THREE_PRIME	false	6	5	MINUS	CCTCTGGCTCATACTCCTGATATTCCTCCTGGGGTGGGTCCTCATAACTCTCCCCTT
SOD2	NM_001024465	6730823	FIVE_PRIME	false	4	3	MINUS	ATCAATCCCCAGCAGTGGAATAAGGCCTGTTGTTCCTTGCAGTGGATCCTGATTTGGAC
TACR1	NM_001058	6666168	CENTER	false	2	1	MINUS	GGAGGAAGTAGATCAGCACAGTCACACAGATGTGGTACACTTTCTCATAAATCTTGTTCGGATGCTCTGGCCATTCG
ABL1	NM_007313	6607158	CENTER	false	3	4	PLUS	GCAGCTTCTTTCAAGAACTCTTCCACCTCCATGGTGTCCTCCTTCAAGGTCTTCACGGCCACCGTC
CASP3	NM_004346	6622272	THREE_PRIME	false	7	6	MINUS	GATGAACCAGGAGCCATCCTTTGAATTTCGCCAAGAATAATAACCAGGTGCTGTGGAGTATGCATACAAGAAGTCGG
FAS	NM_000043	6886514	NA	false	8	NA	PLUS	ATGACACCAATAAACTGTGCAAAGGTCTTTGAGGTAGAGCCTTATTTAAATTCTGC
IL1A	NM_000575	6634703	FIVE_PRIME	false	1	0	MINUS	TGTCTGGAACTTTGGCCATCTTGACTTCTTTGCTGACTCAAACGCCAATGAAATGACTCCCT
INS	NM_001185098	6869713	NA	false	1	NA	MINUS	TGGTACAGCATTGTTCCACAATGCCAGGCTTCTGCAGGGACCCCTCCAGGGCCAAGG
PRKCA	NM_002737	6661457	FIVE_PRIME	false	1	2	PLUS	AAATTCATGGCACCTCTTGTGGACCACAAAACAGCAAACTTGGCACTGGAAGCCTTGTTTCCC
BDNF	NM_001143816	6925057	NA	false	1	NA	MINUS	GCAATGTGGATTCCTGTTCTGATCTAGGTGTTTCTGGGTTGATACAGGGCTCTACCTT
